How to connect temperature sensors
By pressing play, YouTube (Google) loads the video and may store cookies on your device. Privacy notice
The Devices and automatic logs page connects temperature and humidity sensors to your control points. Each reading is added to the control point's log automatically.
Before you start
A sensor feeds one control point and checks each reading against its own minimum and maximum. When a reading falls outside them, a deviation is recorded. One corrective action opens for each spell out of limits. The device type supported is Shelly H&T.
- You are an owner or admin. Other roles see the list only.
- Your package includes ISO 22000.
- The control point the sensor feeds exists on Critical Control Points.
- You have the Shelly H&T and its app at hand.
Step by step
1. Open the page
Open Devices and automatic logs under Food Safety in the menu.
2. Add the device
Press Add a device.
3. Fill in the form
a. Under Name, type a name, such as the fridge it sits in.
b. Under Location, type where it is. This is optional.
c. Under Control point it feeds, choose the control point.
d. Under Unit on the control point, choose the unit, if the control point has named units.
e. Under Minimum (°C) and Maximum (°C), type the limits. Use values between -60 and 100 °C.
f. Under Hours without a reading before it shows "No reading", type a value from 1 to 72. Empty means 3 hours.
g. Under Person told when it goes out of limits, choose a person. With none, only the owner is told.
h. Under Recurring check it satisfies, choose a check, if the sensor replaces a manual round.
4. Save
Press Add device. The card The device's webhook address opens with two addresses.
The addresses are shown only this once.
5. Copy the addresses into the Shelly
a. Press Copy next to temperature.change.
b. In the Shelly app, under Actions, add a webhook on temperature.change with that address.
c. Press Copy next to humidity.change.
d. In the Shelly app, add the second webhook on humidity.change with that address.
e. Press I have copied it.
6. Check the list
The device shows Within limits, Out of limits or No reading, with its last reading. The list refreshes every minute.
Example from a kitchen
What Krateon saves
- The device: name, location, control point, unit, limits, hours without a reading, person told and linked check.
- Every reading, with temperature, humidity and time.
- A monitoring entry on the control point for each reading, marked "Automatic entry (Shelly)". Humidity goes in its note.
- The control point's status and next due time.
- For each spell out of limits, one corrective action. It is numbered and has a target date. It is written in your organisation's language.
- On a linked recurring check, each round the sensor covered.
Check each sensor against a reference thermometer on Calibration.
If something goes wrong
The quoted texts in the first column appear in the app exactly as shown.
| What you see | What it means | What to do |
|---|---|---|
| "This page is not enabled." | ISO 22000 is not switched on for your organisation. | Contact support at hello@krateon.com. |
| "Included in {what}" with the button Ask for it | Your package does not include ISO 22000. | Press Ask for it. |
| "The records could not be loaded." | The device list did not load. | Press Try again. |
| "No devices yet" | No device is connected. | Press Add a device. |
| "Only an owner or an admin can add a device." | Your role cannot add devices. | Ask an owner or admin. |
| "Add a control point first" | No control point exists. | Add the control point on Critical Control Points, then come back. |
| "The minimum must be below the maximum, in °C." | The limits are not numbers, or the minimum is not below the maximum. | Correct the limits. |
| "Limits must be between -60 and 100 °C" | A limit is out of range. | Type limits from -60 to 100 °C. |
| "Hours without a reading must be between 1 and 72" | The hours value is out of range. | Type a value from 1 to 72. |
| "Never reported" | The Shelly has not sent a reading. | Check the two webhooks in the Shelly app. |
| No reading | No reading came in within the set hours. | Check the Shelly and its two webhooks in the Shelly app. |
| Lost the webhook address | The address is shown only once. | On the device row, press New webhook address. The old address stops working at once. Copy the new one into the Shelly. |