Process Criteria Registry

How you add operational processes to the Process Criteria Registry, set their acceptance criteria and thresholds, and edit, filter or delete them.

What it does

This article explains how you add an operational process to the "Process Criteria Registry" and set the acceptance criteria it has to meet.

The screen keeps one row per operational process. A row holds the owner, the trigger, the review cadence, the evidence location, the standard references and a list of acceptance criteria. Each criterion has a label and a threshold. The labels quoted here are the ones shown when ISO 9001 is in view.

The screen shows, from top to bottom:

  • A line naming ISO 9001:2026 and clause 8.1(a), the heading "Process Criteria Registry" and a short description. A "Saved" mark appears under the heading for a moment after each change is saved.
  • Buttons. "Generate with AI" and "Add Process". While the register is empty, a button to add the standard processes is also shown.
  • Four tiles. "Processes", "Active processes", "Criteria defined" and "Critical processes".
  • A category filter. It starts on "All categories". The count next to it reads "{n} of {total}": the rows shown out of all rows.
  • The list of processes. Each row shows the name, the criticality, the category, the number of criteria, the description and the line "Owner: {owner} · Trigger: {trigger}". Select a row to open its details.

Every member of the organisation can open the screen. The owner, admins and members can add and change processes and criteria. Only the owner and admins can delete a process. Contributors and viewers cannot save changes. A viewer sees the notice "Read-only access" at the top of the screen.

Who uses it and when

Use this screen to write down, for each operational process, what "done well" means and how you check it. It is usually kept by the person who looks after the quality system, with the owners of each process.

To fill an empty register quickly, from the standard processes or with AI, see "Start the Process Criteria Registry".

This register is separate from the "Process Map". A process added on one screen does not appear on the other.

How it works

To open the screen, open the "All modules" page and select "Operational planning & control" under "ISO 9001". The screen is not in the task menu.

Add a process

  1. Select "Add Process". The "Add Process" window opens.
  2. Fill in "Process name *". This field is required.
  3. Fill in "Description".
  4. Choose a "Category" and a "Criticality". They start on "Other" and "Medium".
  5. Fill in "Owner", "Trigger", "Evidence location" and "Review cadence".
  6. Under "Linked page", choose the page where the work of this process is recorded, or leave "None".
  7. Fill in "Standard references (clauses, controls)".
  8. Select "Add".

The window notes: "Criteria are added after creation, inside the process row."

Set the acceptance criteria

  1. Select the process row to open its details.
  2. Under "Acceptance Criteria", select "Add criterion". An empty criterion appears, numbered "#1", "#2" and so on.
  3. In the first field, type the label, for example a response time.
  4. In the second field, type the threshold, for example under 1 hour.

Each change in these two fields is saved as you type. The "Saved" mark appears under the heading.

To remove a criterion:

  1. Select the bin icon at the end of its row.
  2. In the window that opens, select "Remove". The window says "You can add it again later.".

Edit a process

  1. Select the process row to open its details.
  2. Select "Edit". The "Edit Process" window opens.
  3. Change the fields you need.
  4. Select "Save".

To close the window without saving, select "Cancel", select the close button, or click outside the window.

Delete a process

  1. Select the process row to open its details.
  2. Select "Delete".
  3. In the window that opens, select "Delete" again. The window says "This cannot be undone.".

Only the owner and admins can delete a process.

Filter the list

Choose a category in the filter. The list shows only the processes of that category. Choose "All categories" to show them all again.

When a process has a linked page, its details show "Go to linked module". Select it to open that page.

Expected outcome

The process appears in the list. The tiles update. When you open the row, its criteria are listed with their labels and thresholds.

  • "Criteria defined". The tile counts the criteria of all processes in view.
  • Measurement. To decide what you measure and how often, see "Metrics & Measurement Catalog".
  • Process Map. To map how your processes connect, see "Process Map".

What counts as a failure

  • After "Add" or "Save", the window stays open and an error message appears.
  • An error message with the title "The criterion was not saved" appears after a change.
  • After "Delete", the process comes back in the list.
  • An error message with the title "Load process criteria" appears when you open the screen. The buttons stay disabled.

Troubleshooting

The messages in the first column appear exactly as quoted.

MessagePossible causeWhat to do
"Required: {fields}""Process name *" is empty. In place of {fields}, the message shows the field name.Fill in the process name, then select "Add" again.
"The criterion was not saved" with "Your role does not allow this change. Saving needs edit rights on this module, and deleting a record or changing the organisation's set-up needs an admin. Ask an admin of your organisation."Your role cannot save on this screen, or you tried to delete as a member.Ask an admin of your organisation to make the change.
"The criterion was not saved" with "Your changes are still on this page. Try again."The change was not saved. The cause is not known.Try the change again. If it fails again, refresh the page.
"Load process criteria"The register could not be read. The cause is not known.Refresh the page.
"Something went wrong. Please try again."General message when the app has no more specific one. The cause is not known.Refresh the page and try again.

If you contact support at hello@krateon.com, include the name of your organisation, the name of the process, the message you saw and the date and time.

Workarounds

  • A change to a criterion was not saved. Type it again. The field is saved on each change.
  • You need the register filled quickly. Start from the standard processes, then change what does not fit. See "Start the Process Criteria Registry".

Redundancy and fallbacks

  • Process. It is saved when you select "Add" or "Save". Closing the window discards what you typed.
  • Criteria. A new criterion is saved as soon as you select "Add criterion". Its label and threshold are saved as you type.
  • Deleted process. It is removed with all its criteria. The screen keeps no history of changes.
  • Linked page. It is only a link to another page. Nothing is copied between the two.